skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Creators/Authors contains: "Maurina, Gabriele"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Abstract Regression test selection (RTS) approaches reduce the cost of regression testing of evolving software systems. Existing RTS approaches based on UML models use behavioral diagrams or a combination of structural and behavioral diagrams. However, in practice, behavioral diagrams are incomplete or not used. In previous work, we proposed a fuzzy logic based RTS approach called FLiRTS that uses UML sequence and activity diagrams. In this work, we introduce FLiRTS 2, which drops the need for behavioral diagrams and relies on system models that only use UML class diagrams, which are the most widely used UML diagrams in practice. FLiRTS 2 addresses the unavailability of behavioral diagrams by classifying test cases using fuzzy logic after analyzing the information commonly provided in class diagrams. We evaluated FLiRTS 2 on UML class diagrams extracted from 3331 revisions of 13 open-source software systems, and compared the results with those of code-based dynamic (Ekstazi) and static (STARTS) RTS approaches. The average test suite reduction using FLiRTS 2 was 82.06%. The average safety violations of FLiRTS 2 with respect to Ekstazi and STARTS were 18.88% and 16.53%, respectively. FLiRTS 2 selected on average about 82% of the test cases that were selected by Ekstazi and STARTS. The average precision violations of FLiRTS 2 with respect to Ekstazi and STARTS were 13.27% and 9.01%, respectively. The average mutation score of the full test suites was 18.90%; the standard deviation of the reduced test suites from the average deviation of the mutation score for each subject was 1.78% for FLiRTS 2, 1.11% for Ekstazi, and 1.43% for STARTS. Our experiment demonstrated that the performance of FLiRTS 2 is close to the state-of-art tools for code-based RTS but requires less information and performs the selection in less time. 
    more » « less